Dabeka R W, McKenzie A D, Conacher H B
J Assoc Off Anal Chem. 1979 Sep;62(5):1065-9.
A simple and accurate method was developed for routine determination of fluoride in foods. Hydrogen fluoride is diffused 20 hr at 50 degrees C from fresh or freeze-dried samples (0.1 g dry wt) in polystyrene petri dishes containing 2 mL 40% HCIO4 and 0.3 g Ag2SO4, and is absorbed on the lids, previously spotted with 0.1 mL 0.5M NaOH. The absorbent layer is dissolved in 2 mL buffer solution, and the fluoride is measured potentiometrically. The method was verified by analysis of NBS Standard Reference Materials; recovery from 28 spiked infant foods (average = 99%, range = 75-135%); and comparison of results with colorimetry results for the same diffusates, after modification to handle 1 g samples. Relative standard deviations varied from 4 to 20% day to day. Detection limits were below 0.05 microgram/g dry weight.
开发了一种简单准确的方法用于常规测定食品中的氟化物。在50℃下,将新鲜或冷冻干燥的样品(0.1g干重)置于含有2mL 40%高氯酸和0.3g硫酸银的聚苯乙烯培养皿中,使氟化氢扩散20小时,氟化氢被吸收在预先滴有0.1mL 0.5M氢氧化钠的盖子上。吸收层溶解于2mL缓冲溶液中,用电位法测定氟化物。通过分析NBS标准参考物质验证了该方法;从28种加标婴儿食品中回收(平均=99%,范围=75 - 135%);在对方法进行修改以处理1g样品后,将相同扩散物的结果与比色法结果进行比较。相对标准偏差每天在4%至20%之间变化。检测限低于0.05微克/克干重。