Preussner S, Roewer J
Folia Haematol Int Mag Klin Morphol Blutforsch. 1975;102(6):690-6.
A haemolytic transfusion incident caused by anti-Jka is reported about. In a 56 year old patient suffering from chronic iron deficiency anaemia an immunization in the Kidd system has taken place within 9 days. In the course of this immunization the fourth incompatible blood transfusion caused a severe transfusion incident. The necessity of serological compatibility testing by the indirect antiglobulin or enzyme test and the significance of making a strict indication for blood transfusions are referred to.