Guisantes J A, Picardo N G
Rev Med Univ Navarra. 1979 Sep;23(3):57-60.
A new variant of the latex agglutination test using latex particles of 0,81 mu diameter is described. Hidatid cyst fluid antigen standardized by immunoelectrophoretic analysis was used. Fifty-one human sera from surgically confirmed hydatidosis and ninety control sera from non-hydatid diseases and healthy donors were studied. The method showed a sensibility of 86,2% and a global inespecificity of 1,1%. A human case of teniasis by Taenia saginata was positive. General considerations about the interpretation of results in human hydatid disease serology are made.
本文描述了一种使用直径为0.81微米的乳胶颗粒的新型乳胶凝集试验。使用经免疫电泳分析标准化的包虫囊肿液抗原。研究了51份经手术确诊为包虫病的人血清以及90份来自非包虫病患者和健康献血者的对照血清。该方法的敏感性为86.2%,总体非特异性为1.1%。一例由牛带绦虫引起的绦虫病患者的检测结果呈阳性。文中还对人类包虫病血清学检测结果的解读进行了一般性讨论。