J Clin Pathol. 1970 Sep;23(6):540-4. doi: 10.1136/jcp.23.6.540.
Several automatic methods have been described for complement-fixation tests. However, each of these methods presents some inconvenience either due to cross contamination or to limited sensitivity. The new method consists basically in separating clearly the fixation stage from the haemolytic stage by using two different sampler plates placed on the same sampler. By this procedure, it becomes possible to obtain a very high sensitivity. The serologist may set the temperature and the duration of the reaction according to the properties of the tests under study. In addition, the sampling rate can be raised to 120 analyses per hour.
已经描述了几种用于补体结合试验的自动方法。然而,这些方法中的每一种都存在一些不便之处,要么是由于交叉污染,要么是由于灵敏度有限。新方法主要包括通过使用放置在同一采样器上的两个不同采样板,将固定阶段与溶血阶段清晰地分开。通过这个程序,可以获得非常高的灵敏度。血清学家可以根据所研究试验的特性设置反应温度和持续时间。此外,采样率可以提高到每小时120次分析。