Suppr超能文献

含碘造影剂对选定的体外甲状腺检测程序的影响(作者译)

[The effect of contrast media containing iodine on selected in vitro thyroid test procedures (author's transl)].

作者信息

Bockslaff H, Brase A, Haindl H, Körber G

出版信息

MMW Munch Med Wochenschr. 1976 Jan 2;118(1):1-6.

PMID:55963
Abstract

The effect of 6 commonly used contrast media on the results of 3 different methods for determination of thyroid hormone concentration in the serum is examined in vivo. T4 determination by column chromatography proved to be very liable to distortion for contrast media. With some contrast media the Res-O-Mat-ETR test proved unreliable. T4 determination by means of protein binding analysis is not affected by contrast media in the direction of false raised values.

摘要

在体内研究了6种常用造影剂对3种不同方法测定血清甲状腺激素浓度结果的影响。柱色谱法测定T4结果显示,造影剂很容易导致结果失真。对于某些造影剂,Res-O-Mat-ETR检测结果不可靠。通过蛋白质结合分析测定T4不受造影剂影响而出现假性升高值。