Fellows K E, Keane J F, Freed M D
Circulation. 1977 Sep;56(3):485-90. doi: 10.1161/01.cir.56.3.485.
Simple and compound sagittally angled views of the heart obtained cineangiocardiographically with a parallelographic U-arm device were evaluated clinically in 132 patients with congenital heart disease. The principle advantage of the apparatus was the case with which axial and oblique projections were obtained without repositioning of the patient, although rotation and angulation of the image intensifier-X-ray tube unit resulted in some increase in scattered radiation. Certain angled views, particularly the 40 degree cranial and the compound 25 degrees cranial/70 degrees left oblique projections, were better than standard frontal and lateral views for visualization of pulmonary arteries in the mediastinum, in ventricular septal defects and anomalies of the left ventricular outflow tract.
使用平行U型臂装置通过心血管造影术获得的心脏简单和复合矢状位倾斜视图,在132例先天性心脏病患者中进行了临床评估。该设备的主要优点是无需重新安置患者即可获得轴向和斜位投影,尽管图像增强器-X射线管单元的旋转和角度调整会导致散射辐射有所增加。某些倾斜视图,特别是40度头位和复合25度头位/70度左斜位投影,在观察纵隔内肺动脉、室间隔缺损和左心室流出道异常方面比标准的正位和侧位视图更好。