Balabanova S, Pohlandt F
Klin Padiatr. 1978 Mar;190(2):151-7.
The precision and accuracy of 21 methods in clinical chemistry (sodium, potassium, calcium, chloride, phosphorus, iron, copper, bilirubin, uric acid, urea, creatinine, total serum protein, triglycerides, glutamate-oxalacetate-transaminase, glutamate-pyruvate-transaminase, alpha-hydroxybutyrate-dehydrogenase, alkaline phosphatase, lactate dehydrogenase, gamma-glutamyl-transpeptidase, acid phosphatase, amylase) were studied after diluting samples 1 : 2 and 1 : 4. Dilution of 1 : 2 did not show any significant effect on the precision and accuracy of the studied methods. In case of chloride, phosphorus, iron, bilirubin, uric acid, urea, creatinine, total serum protein, triglycerides, glutamate-oxalacetate-transaminase and alkaline phosphatase reliable results were obtained also after 1 : 4 dilution.
在将样本按1:2和1:4稀释后,研究了临床化学中21种方法(钠、钾、钙、氯、磷、铁、铜、胆红素、尿酸、尿素、肌酐、总血清蛋白、甘油三酯、谷草转氨酶、谷丙转氨酶、α-羟丁酸脱氢酶、碱性磷酸酶、乳酸脱氢酶、γ-谷氨酰转肽酶、酸性磷酸酶、淀粉酶)的精密度和准确度。1:2稀释对所研究方法的精密度和准确度未显示出任何显著影响。对于氯、磷、铁、胆红素、尿酸、尿素、肌酐、总血清蛋白、甘油三酯、谷草转氨酶和碱性磷酸酶,在1:4稀释后也获得了可靠的结果。