• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Serum plasminogen and lung surfactant in the respiratory distress syndrome.

作者信息

Singer A D, Thibeault D W, Hobel C J, Heiner D C

出版信息

Pediatr Res. 1977 Feb;11(2):119-23. doi: 10.1203/00006450-197702000-00008.

DOI:10.1203/00006450-197702000-00008
PMID:576497
Abstract

Plasminogen, total protein, and surface-active material were measured in amniotic fluid in 112 pregnancies at 11-42 weeks' gestation. In 65 of these pregnancies, cord blood was also analyzed for serum plasminogen and total protein. Plasminogen was detected in 25 of 114 amniotic fluid samples, and 23 came from pregnancies of less than 37 weeks' gestation. Plasminogen was found in 15 of 32 amniotic fluid samples from pregnancies with complications, but only in 10 of 80 "uncomplicated" pregnancies. The mean cord serum plasminogen was relatively constant in births or abortuses of 17 to 30 weeks' gestation, but was present in increasing amounts in births of gestational ages from 30 to 40 weeks. The concentration of plasminogen in cord serum was directly related to the cord total protein (r = 0.7513, P less than 0.001). The cord plasminogen concentration was significantly higher in infants with a positive foam stability test (5.6 +/- 0.3 mg/100 ml) than in the combined group of infants with negative and intermediate tests (4.3 +/- 0.16, P less than 0.005). However, infants with a positive foam stability also had a significantly greater gestational age than infants with a negative or intermediate foam stability test. With one exception, infants with a low cord plasminogen (below 4 mg/100 ml) developed respiratory distress syndrome (RDS) only if amniotic fluid surfactant was low. The data suggest that low levels of serum plasminogen are correlated with severe lung disease only in the presence of surfactant deficiency.

摘要

相似文献

1
Serum plasminogen and lung surfactant in the respiratory distress syndrome.
Pediatr Res. 1977 Feb;11(2):119-23. doi: 10.1203/00006450-197702000-00008.
2
Alpha1-antitrypsin in amniotic fluid and cord blood of preterm infants with the respiratory distress syndrome.
J Pediatr. 1976 Jan;88(1):87-93. doi: 10.1016/s0022-3476(76)80736-6.
3
Foam-stability test on gastric aspirate and the diagnosis of respiratory-distress syndrome.胃液泡沫稳定性试验与呼吸窘迫综合征的诊断
N Engl J Med. 1975 Aug 28;293(9):413-6. doi: 10.1056/NEJM197508282930901.
4
Improving the prediction of surfactant deficiency in very low-birthweight infants with respiratory distress.改善对患有呼吸窘迫的极低出生体重儿表面活性剂缺乏症的预测。
J Perinatol. 1992 Jun;12(2):129-33.
5
Surfactant associated protein (SAP-35) in amniotic fluid from diabetic and nondiabetic pregnancies.糖尿病和非糖尿病孕妇羊水中的表面活性物质相关蛋白(SAP - 35)
Obstet Gynecol. 1987 Jul;70(1):94-8.
6
Amniotic fluid shake test versus lecithin-sphingomyelin ratio in the antenatal prediction of respiratory distress syndrome.羊水振荡试验与卵磷脂 - 鞘磷脂比值在产前预测呼吸窘迫综合征中的比较
Z Geburtshilfe Perinatol. 1977 Aug;181(4):260-3.
7
Neonatal respiratory distress syndrome as a function of gestational age and an assay for surfactant-to-albumin ratio.新生儿呼吸窘迫综合征与胎龄的关系及表面活性剂与白蛋白比值的检测
Obstet Gynecol. 2004 Mar;103(3):463-8. doi: 10.1097/01.AOG.0000113622.82144.73.
8
[The value of various investigations of amniotic fluid in the estimation of fetal maturity (author's transl)].[羊水的各种检查在评估胎儿成熟度中的价值(作者译)]
Wien Klin Wochenschr. 1975 Sep 5;87(16):507-10.
9
[Relationship between total bile acid concentration and fetal pulmonary surfactant in intrahepatic cholestasis of pregnancy].[妊娠肝内胆汁淤积症中总胆汁酸浓度与胎儿肺表面活性物质的关系]
Zhonghua Fu Chan Ke Za Zhi. 2011 May;46(5):324-8.
10
Studies on the modified foam stability test. Effects of blood and meconium and comparison with Clements' shake test.改良泡沫稳定性试验的研究。血液和胎粪的影响以及与克莱门茨摇晃试验的比较。
Diagn Gynecol Obstet. 1981 Spring;3(1):9-14.