Suppr超能文献

雷诺现象中的血液粘度异常。

Abnormal blood viscosity in Raynaud's phenomenon.

作者信息

Goyle K B, Dormandy J A

出版信息

Lancet. 1976 Jun 19;1(7973):1317-8. doi: 10.1016/s0140-6736(76)92651-9.

Abstract

The exact cause of Raynaud's phenomenon is still unknown. Since the principal feature of this condition is the precipitation of the attacks by cold, blood viscosity was measured in ten patients and in ten normal controls at 27 degrees C and 37 degrees C. The viscosity of the patients' blood was significantly higher (p less than 0.05) at 27 degrees C than that of the controls when measured at a low shear-rate (0.77 s-1). This, as well as the higher yield stress of the patients' blood, suggests that Raynaud's phenomenon may be caused by an abnormal local increase in the viscosity and yield stress of the blood in response to a fall in temperature.

摘要

雷诺现象的确切病因尚不清楚。由于这种病症的主要特征是寒冷引发发作,因此在27摄氏度和37摄氏度下对10名患者和10名正常对照者进行了血液粘度测量。在低剪切速率(0.77秒-1)下测量时,患者血液在27摄氏度时的粘度显著高于对照组(p小于0.05)。这一点,以及患者血液较高的屈服应力,表明雷诺现象可能是由于温度下降时血液粘度和屈服应力局部异常增加所致。