• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Kits for enzyme determinations compared: relation between composition and quality.

作者信息

Peters F P, Hafkenscheid J C

出版信息

Clin Chem. 1984 Oct;30(10):1625-30.

PMID:6148161
Abstract

Kits of five different suppliers, composed according to the Dutch recommendations for determination of the enzyme activity of alanine aminotransferase, aspartate aminotransferase, lactate dehydrogenase, gamma-glutamyltransferase, alkaline phosphatase, and creatine kinase, were intercompared. Activity concentrations of the enzymes in human sera were measured under defined conditions, evaluated, and related to the actual composition of the kits. Concentrations of all kit components were determined by various analytical techniques. The overall results of the activity measurements and the composition of at least three kits inter-agree well. We found deviations as great as 10% in our analytical evaluation of the kits of the other two suppliers, which can partly be accounted for.

摘要

相似文献

1
Kits for enzyme determinations compared: relation between composition and quality.
Clin Chem. 1984 Oct;30(10):1625-30.
2
Normal serum activities of some diagnostic enzymes in dromedary camel in Sudan.苏丹单峰骆驼某些诊断酶的正常血清活性
Vet Res Commun. 1987;11(3):201-3. doi: 10.1007/BF00570916.
3
Two dry-reagent systems evaluated for determinations of enzyme activities.
Clin Chem. 1988 Jan;34(1):155-7.
4
[Evaluation of enzyme modules of the Beckman Astra 8].[贝克曼Astra 8酶模块的评估]
Ann Biol Clin (Paris). 1986;44(4):389-96.
5
Evaluation of commercial enzyme reagent kits by use of a semiautomated chemistry analyzer.
Am J Clin Pathol. 1979 Aug;72(2):151-5. doi: 10.1093/ajcp/72.2.151.
6
Decreased activity of commonly measured serum enzymes: causes and clinical significance.常用血清酶活性降低:原因及临床意义。
Am J Med Technol. 1983 Apr;49(4):241-5.
7
Normal values of enzyme activities during pregnancy.孕期酶活性的正常数值。
Z Klin Chem Klin Biochem. 1974 May;12(5):262-3.
8
Serum enzyme levels in healthy old people.健康老年人的血清酶水平。
Ann Clin Biochem. 1977 Mar;14(2):118-9. doi: 10.1177/000456327701400121.
9
[The behaviour of some serologic enzymes during hemodialytic treatment].[血液透析治疗期间某些血清酶的行为]
Quad Sclavo Diagn. 1977 Sep;13(3):350-8.
10
Reference values for six enzymes in plasma from newborns and women at delivery.新生儿及分娩期女性血浆中六种酶的参考值。
Scand J Clin Lab Invest. 1979 Dec;39(8):777-84. doi: 10.1080/00365517909108171.