Hofer H, Mihatsch M J, Guggenheim R, Amsler B, Hasse J, Graedel E
Thorac Cardiovasc Surg. 1981 Feb;29(1):32-7. doi: 10.1055/s-2007-1023437.
Vein bypass grafts in 8 patients were examined by light microscopy (LM) only or, in addition, by transmission electron microscopy (TEM) and scanning electron microscopy (SEM) before stretching, after stretching and immediately before implantation. Before stretching, the endothelium showed only discrete changes and detachment of the endothelium was rare. After stretching severe endothelial damage was evident, including loss of large areas of endothelium and extensive endothelial tears. Before implantation there had been an extension of the tears and the endothelial detachment in individual preparations. The most important factor causing damage is stretching of the vein. The incubation medium may also play a significant role. Damage incurred before operation or during removal, and hypoxia are of lesser importance. By avoiding endothelial damage it should be possible to limit the occurrence of early postoperative thrombosis and possibly severe late changes as well.
对8例患者的静脉搭桥移植物在拉伸前、拉伸后及植入前即刻仅通过光学显微镜(LM)检查,或另外通过透射电子显微镜(TEM)和扫描电子显微镜(SEM)检查。拉伸前,内皮仅显示离散性改变,内皮剥脱少见。拉伸后,严重的内皮损伤明显,包括大片内皮缺失和广泛的内皮撕裂。植入前,个别标本中撕裂和内皮剥脱有所扩展。造成损伤的最重要因素是静脉拉伸。孵育培养基也可能起重要作用。手术前或取材过程中造成的损伤以及缺氧的重要性较低。通过避免内皮损伤,应该有可能限制术后早期血栓形成的发生,并可能也限制严重的晚期改变。