Suppr超能文献

[用于高密度脂蛋白胆固醇测定的沉淀法准确性评估]

[Evaluation of the accuracy of precipitation methods for HDL cholesterol determination].

作者信息

Barban G, Montanari D, Bertolini S, Reggiani E, Chiodini G, Elicio N, Jacopino G E, Balestreri R

出版信息

Boll Soc Ital Biol Sper. 1982 Feb;58(3-4):99-105.

PMID:6175325
Abstract

Several methods for HDL-Cholesterol determination have been proposed; the over-floating cholesterol evaluation after non-HDL lipoproteins precipitation by polyanions with bivalent cations or neutral polymers is practical and not expensive, but it's accuracy and precision must be strictly control led. The Authors, after a review and a quality-check of the most used methods, conclude that the best accuracy for HDL-Cholesterol determination is provided by Dextransulphate-Mg-chloride and Phosphotungstate-Mg-chloride at pH 7,5.

摘要

已经提出了几种测定高密度脂蛋白胆固醇(HDL-胆固醇)的方法;通过带有二价阳离子的聚阴离子或中性聚合物沉淀非HDL脂蛋白后进行的上浮胆固醇评估既实用又经济,但必须严格控制其准确性和精密度。作者在对最常用的方法进行综述和质量检查后得出结论,在pH 7.5时,硫酸葡聚糖-氯化镁和磷钨酸-氯化镁法测定HDL-胆固醇的准确性最高。