Panrucker D E, Lorscheider F L
Biochim Biophys Acta. 1982 Jul 26;705(2):184-91. doi: 10.1016/0167-4838(82)90177-7.
A double-antibody radioimmunoassay (RIA) to acute-phase alpha 2-macroglobulin was developed for the quantitation of this large macromolecule in physiological fluids. The primary receptor for the RIA was a monospecific antiserum to purified acute-phase alpha 2-macroglobulin which produced a high titre (7.5 . 10(6)) antibody with a strong affinity for rat acute-phase alpha 2-macroglobulin (Ka = 1.24 . 10(11)) as measured by Scatchard analysis. The validity of the assay was confirmed by specificity for rat alpha 2-macroglobulin measured in various physiological fluids as assessed by parallel dose-response curves; and accuracy, measured by the analytical recovery of alpha 2-macroglobulin by the RIA in serum (104 +/- 7%) and buffer (103 +/- 7%), and the correlation (R = 0.999) of measurements of acute-phase alpha 2-macroglobulin-containing samples measured in serum and buffer. Reference acute-phase serum measured by this RIA and by rocket immunoelectrophoresis were 98.6% in agreement. Radioimmunoassay sensitivity was estimated at less than 1.0 ng alpha 2-macroglobulin/ml, measured over a range of 0-160 ng. Precision was assessed by intraassay (2.99 +/- 0.97%) and interassay (8.76 +/- 2.64%) variation. Evaluation confirmed that quantitation of rat acute-phase alpha 2-macroglobulin by this RIA met the criteria of sensitivity, validity and precision.
已开发出一种用于急性期α2-巨球蛋白的双抗体放射免疫测定法(RIA),用于定量生理体液中的这种大分子。该RIA的主要受体是针对纯化的急性期α2-巨球蛋白的单特异性抗血清,通过Scatchard分析测定,它产生了高滴度(7.5×10⁶)的抗体,对大鼠急性期α2-巨球蛋白具有很强的亲和力(Ka = 1.24×10¹¹)。通过平行剂量反应曲线评估,该测定法对各种生理体液中测量的大鼠α2-巨球蛋白的特异性证实了其有效性;通过RIA在血清(104±7%)和缓冲液(103±7%)中对α2-巨球蛋白的分析回收率以及血清和缓冲液中测量的含急性期α2-巨球蛋白样品测量值的相关性(R = 0.999)来衡量其准确性。用该RIA和火箭免疫电泳法测量的参考急性期血清结果一致性为98.6%。在0至160 ng的范围内测量,放射免疫测定法的灵敏度估计小于1.0 ngα2-巨球蛋白/ml。通过批内变异(2.99±0.97%)和批间变异(8.76±2.64%)评估精密度。评估证实,通过该RIA对大鼠急性期α2-巨球蛋白的定量符合灵敏度、有效性和精密度标准。