A dedicated microcomputer-based instrument for interval analysis of multicomponent wave forms in single fibre EMG.

作者信息

Davis G R, Brown I T, Schwartz M S, Swash M

出版信息

Electroencephalogr Clin Neurophysiol. 1983 Jul;56(1):110-3. doi: 10.1016/0013-4694(83)90013-5.

Abstract

We have developed a self-contained microprocessor-based instrument compatible with conventional EMG equipment for the analysis of multicomponent SFEMG wave forms suitable for single operator use. Intervals between 4 components of a MUAP can be analysed using 3 types of threshold or window triggers. The amplitude, duration and polarity of each of these triggers can be varied independently. The instrument is portable and useful in the clinical setting.

摘要

我们开发了一种基于微处理器的独立仪器,它与传统肌电图设备兼容,用于分析适用于单人操作的多成分单纤维肌电图波形。运动单位动作电位(MUAP)的4个成分之间的间隔可以使用3种类型的阈值或窗口触发进行分析。这些触发的每个的幅度、持续时间和极性可以独立变化。该仪器便于携带,在临床环境中很有用。

相似文献

1
A dedicated microcomputer-based instrument for interval analysis of multicomponent wave forms in single fibre EMG.
Electroencephalogr Clin Neurophysiol. 1983 Jul;56(1):110-3. doi: 10.1016/0013-4694(83)90013-5.
2
Jittermeter--a microcomputer-based system for single fibre electromyography.
Int J Biomed Comput. 1979 Nov;10(6):451-9. doi: 10.1016/0020-7101(79)90027-8.
4
Single unit retrieval in microneurography: a microprocessor-based device controlled by an operator.
J Neurosci Methods. 1988 Jun;24(2):137-44. doi: 10.1016/0165-0270(88)90057-x.
5
Personal-computer-based single-fibre EMG jitter analysis system.
Med Biol Eng Comput. 1990 Nov;28(6):607-12. doi: 10.1007/BF02442618.
6
A measuring system for EMG silent period using a microcomputer.
IEEE Trans Biomed Eng. 1982 Nov;29(11):713-8. doi: 10.1109/TBME.1982.325001.
7
A duration matching method for the measurement of jitter in single fibre EMG.
Electroencephalogr Clin Neurophysiol. 1983 Nov;56(5):515-20. doi: 10.1016/0013-4694(83)90236-5.
8
A microcomputer system for on-line analysis of the end-plate potential data.
Brain Res Bull. 1981 Jul;7(1):97-9. doi: 10.1016/0361-9230(81)90104-0.
9
Reference values for voluntary and stimulated single-fibre EMG using concentric needle electrodes: a multicentre prospective study.
Clin Neurophysiol. 2012 Mar;123(3):613-20. doi: 10.1016/j.clinph.2011.07.044. Epub 2011 Sep 1.

引用本文的文献

1
Cancer-associated myasthenic (Eaton-Lambert) syndrome: distribution of abnormality and effect of treatment.
J Neurol Neurosurg Psychiatry. 1984 Aug;47(8):806-12. doi: 10.1136/jnnp.47.8.806.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验