在一名儿童中使用可脱卸球囊经导管封堵Blalock-Taussig分流术。

Transcatheter occlusion of a Blalock-Taussig shunt with a detachable balloon in a child.

作者信息

Reidy J F, Baker E, Tynan M

出版信息

Br Heart J. 1983 Jul;50(1):101-3. doi: 10.1136/hrt.50.1.101.

Abstract

A case of transcatheter occlusion of a Blalock-Taussig shunt with a detachable silicone filled balloon is described. This 11 year old boy had previously had a repair of tetralogy of Fallot together with ligation of a large Blalock-Taussig shunt. Though there was a good surgical result, the shunt proved to be incompletely closed leaving a significant left to right shunt. As an alternative to a further operation a silicone filled balloon was detached in the Blalock-Taussig shunt and this successfully closed the fistula.

摘要

本文描述了一例使用可分离的硅胶填充球囊经导管封堵Blalock-Taussig分流术的病例。这名11岁男孩此前接受了法洛四联症修复术及大型Blalock-Taussig分流结扎术。尽管手术效果良好,但分流术被证明未完全闭合,仍存在明显的左向右分流。作为进一步手术的替代方案,在Blalock-Taussig分流术中置入了一个硅胶填充球囊,成功闭合了瘘管。