Bland J, Edison A, Huber J
Eur J Clin Microbiol. 1983 Jun;2(3):249-52. doi: 10.1007/BF02029527.
A disk-diffusion bioassay procedure for the quantitation of norfloxacin in serum, tissue and urine employing Klebsiella pneumoniae ATCC 10031 was developed. When incubated at 28 degrees C, the assay has a sensitivity of 0.2 microgram/ml. Zones of inhibition on assay plates may be measured by hand (ruler, vernier caliper) or by automated image analysis. Urine samples require an initial 1:2 dilution in 0.1N HCl before assay to assure complete solution of the compound. Bioassay values in urine are comparable to those obtained by high performance liquid chromatography.
开发了一种采用肺炎克雷伯菌ATCC 10031对血清、组织和尿液中的诺氟沙星进行定量的纸片扩散生物测定法。在28摄氏度下孵育时,该测定法的灵敏度为0.2微克/毫升。测定平板上的抑菌圈可用手工(直尺、游标卡尺)或自动图像分析进行测量。尿液样本在测定前需要在0.1N盐酸中进行初始1:2稀释,以确保化合物完全溶解。尿液中的生物测定值与通过高效液相色谱法获得的值相当。