Barbu M, Colas-Linhart N, Bok B
Acta Haematol. 1984;71(1):13-7. doi: 10.1159/000206498.
The cellular uptake of technetium 99m was determined on white blood cells (WBC) by autoradiography, after 'cold' tin pyrophosphate prelabelling followed by pertechnetate labelling. The autoradiographic method gave visible tracks of 99mTc internal conversion and Auger electrons. 75 +/- 5% of the treated WBC were labelled but none of the control WBC. The number and length of tracks per cell varied greatly. This was perhaps due to imaging conditions as well as to variations in cell uptake.
在用“冷”焦磷酸锡预标记然后用高锝酸盐标记后,通过放射自显影法测定了99m锝在白细胞(WBC)中的细胞摄取情况。放射自显影法给出了99mTc内转换和俄歇电子的可见轨迹。75±5%的处理过的白细胞被标记,但对照白细胞无一被标记。每个细胞的轨迹数量和长度差异很大。这可能是由于成像条件以及细胞摄取的变化所致。