A clinical evaluation of a prototype positron camera for longitudinal emission tomography.

作者信息

Flower M A, Ott R J, Webb S, Leach M O, Marsden P, Khan O, McCready V R, Bateman J E, Flesher A C, Sharma H L

出版信息

Br J Radiol. 1984 Dec;57(684):1103-17. doi: 10.1259/0007-1285-57-684-1103.

Abstract

A multiwire proportional-chamber positron camera, developed at the Rutherford Laboratory, has been evaluated at The Royal Marsden Hospital. The prototype camera consists of two opposing 30 X 30 cm2 chambers. Longitudinal tomograms of a positron-emitting radioactive distribution placed between the detectors are obtained via back-projection and 2D-deconvolution. Due to the limited stereoscopic angle achieved with stationary detectors, only five planes parallel to the detector faces are reconstructed. A selection of images is presented of phantoms using 68Ga and of patients using 18F, 18F fluorodeoxyglucose and Na124I, to illustrate the tomographic performance of the positron camera. A comparison between back-projected and deconvoluted images shows that the 2D-deconvolution process, which includes filtration of image noise, successfully removes the background due to scattered photons. The spatial resolution achieved depends on the half-height frequency cut-off used in the filtering process, and this parameter was chosen according to the count density in the back-projected images. A qualitative visual comparison was made between the positron images and equivalent single photon studies on the same patient. The results justify further development of this new detector, especially for use with generator-produced positron-emitting radionuclides. Three-dimensional deconvolution resulted in improved tomographic performance for phantom data, but was less successful for patient data. These problems associated with limited-angle tomography will be overcome by multi-view acquisition. This study has shown that a relatively low-cost positron imaging system can be used for routine organ imaging. Further developments in hardware and software should yield images which are superior to those from single-photon planar or tomographic studies.

摘要

相似文献

1
A clinical evaluation of a prototype positron camera for longitudinal emission tomography.
Br J Radiol. 1984 Dec;57(684):1103-17. doi: 10.1259/0007-1285-57-684-1103.
5
The performance of a multiwire proportional chamber positron camera for clinical use.
Phys Med Biol. 1989 Aug;34(8):1043-62. doi: 10.1088/0031-9155/34/8/007.
10
Wire chambers revisited.再探丝室
Eur J Nucl Med. 1993 Apr;20(4):348-58. doi: 10.1007/BF00169813.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验