某公寓楼空气的微生物调查。

Microbial investigation of the air in an apartment building.

作者信息

Simard C, Trudel M, Paquette G, Payment P

出版信息

J Hyg (Lond). 1983 Oct;91(2):277-86. doi: 10.1017/s0022172400060290.

Abstract

The microbial and viral flora in the ventilating ducts of an apartment building was evaluated. Several types of sampler (slit sampler, Andersen sampler, large volume air sampler) were used to evaluate the hourly, weekly and seasonal variation of this flora. The mean bacterial concentration was 17.2 e.f.u./m3 with a maximum level at 07.30 h (41.3 c.f.u./m3) and a minimal concentration in the early afternoon (8 c.f.u./m3). The bacterial concentration observed correlated with the relative humidity in the air-ducts although there were no seasonal differences. The bacteria were mainly gram-positive cocci (73.5%) represented by a large number of Micrococcaceae (47.1%); gram-positive bacilli accounted for 14.2% of the isolates, gram-negative bacilli 12.0% and gram-negative cocci 0.3%. The majority of the bacteria-carrying particles were in the respirable range with 80.4% of them being less than 5 microns. The methods used did not result in the isolation of viruses during the winter sampling period.

摘要

对一栋公寓楼通风管道中的微生物和病毒菌群进行了评估。使用了几种类型的采样器(狭缝采样器、安德森采样器、大容量空气采样器)来评估该菌群的每小时、每周和季节性变化。细菌平均浓度为17.2 e.f.u./m³,在07:30时达到最高水平(41.3 c.f.u./m³),下午早些时候浓度最低(8 c.f.u./m³)。尽管没有季节性差异,但观察到的细菌浓度与风道中的相对湿度相关。细菌主要为革兰氏阳性球菌(73.5%),其中大量为微球菌科(47.1%);革兰氏阳性杆菌占分离菌的14.2%,革兰氏阴性杆菌占12.0%,革兰氏阴性球菌占0.3%。大多数携带细菌的颗粒在可吸入范围内,其中80.4%小于5微米。在冬季采样期间,所使用的方法未分离出病毒。

相似文献

1
Microbial investigation of the air in an apartment building.
J Hyg (Lond). 1983 Oct;91(2):277-86. doi: 10.1017/s0022172400060290.
2
Concentrations of airborne culturable bacteria in 100 large US office buildings from the BASE study.
Indoor Air. 2005;15 Suppl 9:71-81. doi: 10.1111/j.1600-0668.2005.00346.x.
6
Assessment of bioaerosols in swine barns by filtration and impaction.
Curr Microbiol. 2002 Feb;44(2):136-40. doi: 10.1007/s00284-001-0064-y.
7
[The ratios and kinds of clinical bacteria isolated in Taiwan's large-size hospitals].
Zhonghua Min Guo Wei Sheng Wu Ji Mian Yi Xue Za Zhi. 1989 Feb;22(1):46-58.
8
Concentration of airborne endotoxins and airborne bacteria in Chinese rabbit houses.
Berl Munch Tierarztl Wochenschr. 2006 Jan-Feb;119(1-2):40-4.
9
Airborne microbial contents in two types of swine confinement buildings in Quebec.
Am Ind Hyg Assoc J. 1990 Jun;51(6):304-9. doi: 10.1080/15298669091369709.

引用本文的文献

1
Culturable airborne bacteria in outdoor environments in Beijing,China.
Microb Ecol. 2007 Oct;54(3):487-96. doi: 10.1007/s00248-007-9216-3. Epub 2007 Feb 17.
2
Longitudinal study of dust and airborne endotoxin in the home.
Environ Health Perspect. 2000 Nov;108(11):1023-8. doi: 10.1289/ehp.001081023.
3
Indoor climate and air quality in new offices: effects of a reduced air-exchange rate.
Int Arch Occup Environ Health. 1991;63(4):233-9. doi: 10.1007/BF00386371.

本文引用的文献

1
A Study of Air Pollution in New York City.
Am J Public Health Nations Health. 1937 Apr;27(4):321-33. doi: 10.2105/ajph.27.4.321.
2
THE EFFECT OF HUMIDITY ON BETA STREPTOCOCCI (GROUP C) ATOMIZED INTO AIR.
Science. 1942 Sep 18;96(2490):277-8. doi: 10.1126/science.96.2490.277.
3
Bacterial contamination of the air in boot and shoe factories.
Br J Ind Med. 1951 Jan;8(1):8-11. doi: 10.1136/oem.8.1.8.
4
Epidemiology of airborne infection.
Bacteriol Rev. 1961 Sep;25(3):173-81. doi: 10.1128/br.25.3.173-181.1961.
5
CALIBRATION OF A MODIFIED ANDERSEN BACTERIAL AEROSOL SAMPLER.
Appl Microbiol. 1964 Jan;12(1):37-43. doi: 10.1128/am.12.1.37-43.1964.
6
THE SIZE DISTRIBUTION OF AIRBORNE PARTICLES CARRYING MICRO-ORGANISMS.
J Hyg (Lond). 1963 Dec;61(4):385-91. doi: 10.1017/s0022172400020994.
7
Microbiological contamination of hospital air. II. Qualitative studies.
Appl Microbiol. 1962 Nov;10(6):567-71. doi: 10.1128/am.10.6.567-571.1962.
8
Distribution and deposition of inhaled particles in respiratory tract.
Bacteriol Rev. 1961 Sep;25(3):237-40. doi: 10.1128/br.25.3.237-240.1961.
9
New sampler for the collection, sizing, and enumeration of viable airborne particles.
J Bacteriol. 1958 Nov;76(5):471-84. doi: 10.1128/jb.76.5.471-484.1958.
10
The bacterial flora of the air of occupied rooms.
J Hyg (Lond). 1956 Dec;54(4):512-23. doi: 10.1017/s002217240004479x.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验