We previously proposed the insulin sensitivity index, Sl, as an absolute measure of whole body tissue sensitivity to insulin. Sl is defined, in the physiologic range of insulin action, as the effect of insulin to augment glucose's ability to reduce its own plasma level. This parameter can be determined from the frequently sampled intravenous glucose tolerance test (IVGTT) by using a digital computer to find the coefficients of a minimal mathematical model of glucose kinetics. In the present study we compared, in normal dogs, Sl determined from the IVGTT to an analogous parameter [Sl(clamp)] calculated from the euglycemic glucose clamp (EGC). Fifteen pairs of experiments (1 IVGTT and 1 EGC) were performed on 12 animals. IVGTTs: After glucose injection (0.3 g/kg), frequent blood samples were taken over the subsequent 3 h. KG ranged from 1.7 to 4.7%/min, and integrated insulin from 0.4 to 5.9 (mU/ml) min for 0-60 min. Sl varied over a nine-fold range from 1.0 to 9.1 X 10(-4) (min-1)/(microU/ml), with a mean of 4.3 +/- 0.7 X 10(-4). Fractional glucose disappearance rate independent of insulin (p1) was 4.3 +/- 0.5%/min. EGCs: Low-rate insulin infusion (8 mU/min from 1 to 150 min) elevated plasma insulin (INS) from 15 +/- 4 to 43 +/- 10 microU/ml. Glucose was infused (GINF) at 119 +/- 20 mg/min to maintain euglycemia. Moderate insulin infusion (40 mU/min: 151-300 min) further elevated plasma insulin (to 176 +/- 37 microU/ml) and the requisite glucose infusion (to 372 +/- 36 mg/min).(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

我们之前提出胰岛素敏感性指数(SI),作为全身组织对胰岛素敏感性的一种绝对度量。在胰岛素作用的生理范围内,SI被定义为胰岛素增强葡萄糖降低自身血浆水平能力的效应。该参数可通过频繁采样静脉葡萄糖耐量试验(IVGTT),利用数字计算机找到葡萄糖动力学最小数学模型的系数来确定。在本研究中,我们在正常犬中比较了由IVGTT测定的SI与由正常血糖葡萄糖钳夹(EGC)计算出的类似参数[SI(钳夹)]。对12只动物进行了15对实验(1次IVGTT和1次EGC)。IVGTT:注射葡萄糖(0.3 g/kg)后,在随后3小时内频繁采集血样。0至60分钟期间,KG范围为1.7至4.7%/分钟,整合胰岛素范围为0.4至5.9(mU/ml)分钟。SI在1.0至9.1×10⁻⁴(分钟⁻¹)/(微U/ml)的九倍范围内变化,平均值为4.3±0.7×10⁻⁴。不依赖胰岛素的葡萄糖消失率分数(p1)为4.3±0.5%/分钟。EGC:低速率胰岛素输注(1至150分钟为8 mU/分钟)使血浆胰岛素(INS)从15±4升高至43±10微U/ml。以119±20 mg/分钟的速率输注葡萄糖(GINF)以维持正常血糖。中等速率胰岛素输注(40 mU/分钟:151至300分钟)进一步使血浆胰岛素升高(至176±37微U/ml),所需葡萄糖输注量升高(至372±36 mg/分钟)。(摘要截断于250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验