Wladimiroff J W, Stewart P A, Vosters R P
Clin Cardiol. 1984 May;7(5):239-53. doi: 10.1002/clc.4960070501.
Present combined two-dimensional real-time and M-mode echocardiograph systems allow detailed analysis of fetal cardiac structure and function. Standard scanning planes for systematic investigation of various cardiac structures are described. There is a curvilinear increase in left ventricular volume (Qlv), stroke volume (Qlvs), and output Q'lv) during the last trimester of pregnancy with a mean Q'lv value at term of 126 +/- 11 ml/kg/min. Scanning for cardiac defects should preferably be done between 18 and 24 weeks of gestation. In a total of 444 patients referred to our ultrasound unit for ultrasonic analysis of fetal cardiac structure, a total of 13 cardiac defects were diagnosed. The incidence of structural cardiac defects present among those with fetal dysrhythmia was 15%.
目前的二维实时和M型超声心动图系统能够对胎儿心脏结构和功能进行详细分析。文中描述了用于系统检查各种心脏结构的标准扫描平面。妊娠晚期左心室容积(Qlv)、每搏输出量(Qlvs)和心输出量(Q'lv)呈曲线增加,足月时Q'lv的平均数值为126±11毫升/千克/分钟。心脏缺陷的扫描最好在妊娠18至24周之间进行。在总共444名因胎儿心脏结构超声分析转诊至我们超声科的患者中,共诊断出13例心脏缺陷。胎儿心律失常患者中结构性心脏缺陷的发生率为15%。