Sonntag A
Nuklearmedizin. 1983 Feb;22(1):31-8.
Starting from routine renal clearance measurements in a partially shielded whole-body counter, generally applicable algorithms were developed empirically which permit the reconstruction of the total course of retention up to 28 min p.i. from e.g. the 12 min and 24 min values only. By formal differentiation the instantaneous slope of the decline in retention and thus the renal clearance can be calculated employing the whole-body counting principle. Integration yields the possibility of subtracting background from renograms to calculate single renal clearances. The method offers advantages in cases of reduced measurement geometry and/or low count rates.
从部分屏蔽的全身计数器中的常规肾清除率测量开始,通过经验开发了通用算法,这些算法仅根据例如12分钟和24分钟的值就可以重建注射后长达28分钟的保留全过程。通过形式上的微分,可以利用全身计数原理计算保留率下降的瞬时斜率,进而计算肾清除率。积分使得从肾图中减去本底以计算单个肾清除率成为可能。该方法在测量几何条件不佳和/或计数率较低的情况下具有优势。