Abstract

The per cent ionisation curves for the 4 MV photon beam from a Clinac 4 exhibit pronounced enhancement with field size in the build-up region. The source and nature of this increase is investigated by analysing the radiation components of the 4 MV photon beam with a 0.23 T magnetic field. The build-up ionisation curves were measured at 86 cm SSD with a parallel-plate ionisation chamber embedded in a polystyrene phantom. The surface ionisation increases from 18% to 32% as the field size is increased from 4.3 cm X 4.3 cm to 9.7 cm X 32.3 cm. With the electromagnet placed beside the treatment head, the field size dependence reduces to 16% to 24%. This and similar results at 113.2 cm SSD, clearly demonstrate that electrons from the Clinac 4 treatment head are responsible for approximately half the observed increase in the surface ionisation with field size.

摘要

一台Clinac 4的4兆伏光子束在建成区的电离百分比曲线随射野大小呈现出显著增强。通过用0.23特斯拉的磁场分析4兆伏光子束的辐射成分,研究了这种增加的来源和性质。使用嵌入聚苯乙烯模体中的平行板电离室,在源皮距86厘米处测量建成区电离曲线。当射野大小从4.3厘米×4.3厘米增加到9.7厘米×32.3厘米时,表面电离从18%增加到32%。当电磁铁置于治疗头旁边时,射野大小依赖性降低到16%至24%。在源皮距113.2厘米处的这一结果以及类似结果清楚地表明,Clinac 4治疗头产生的电子约占表面电离随射野大小增加量的一半。