We have used automated differential leucocyte counts by volume analysis for the past six months after initial evaluation had shown several advantages--namely, accuracy, simplicity, speed, and low cost. We describe the operation of the Coulter Channelyzer Model C-1000, which is linked to a Coulter Model S cell counter, analyse the cost, and comment on the clinical and laboratory consequences of adopting this method.

摘要

在初步评估显示出诸如准确性、简易性、速度和低成本等若干优点之后,我们在过去六个月中一直使用通过体积分析进行的白细胞自动分类计数。我们描述了与库尔特S型细胞计数器相连的库尔特C-1000型通道分析仪的操作,分析了成本,并对采用该方法的临床和实验室结果进行了评论。

相似文献

2
Method for the automation of equine differential leucocyte counts.
Equine Vet J. 1981 Apr;13(2):115-8. doi: 10.1111/j.2042-3306.1981.tb04133.x.
8
Letter: Differential leucocyte-counts on Coulter counter model S.
Lancet. 1976 May 22;1(7969):1134-5. doi: 10.1016/s0140-6736(76)99035-8.
9
The Coulter Counter leukocyte differential.
Blood Cells. 1985;11(2):203-40.

本文引用的文献

2
Automated differential leucocyte counting: the present state of the art.
Br J Haematol. 1977 Apr;35(4):481-5. doi: 10.1111/j.1365-2141.1977.tb00614.x.
3
Letter: Differential leucocyte-counts on Coulter counter model S.
Lancet. 1976 May 22;1(7969):1134-5. doi: 10.1016/s0140-6736(76)99035-8.
4
Simple method for automating the differential leucocyte-count.
Lancet. 1975 Mar 1;1(7905):492-3. doi: 10.1016/s0140-6736(75)92834-2.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验