A comparative study was carried out in 790 women undergoing one of the 3 most frequently used laparoscopic sterlization techniques: high-frequency unipolar electrocoagulation of the tubes, application of silastic rings or spring-loaded clips to the tubes. The technical problems and per- and postoperative (early) complications are assessed. The use of high-frequency unipolar current has been superseded by today's mechanical and non-electrical sterilization methods. The spring-loaded clip method appears to be a sterilization technique with a minimum of severe complications, and theoretically the greatest chances for possible refertilization.

摘要

对790名接受3种最常用腹腔镜绝育技术之一的女性进行了一项比较研究:输卵管高频单极电凝术、输卵管硅橡胶环置入术或弹簧夹夹闭术。评估了技术问题以及术中和术后(早期)并发症。高频单极电流的使用已被当今的机械和非电绝育方法所取代。弹簧夹夹闭术似乎是一种严重并发症最少的绝育技术,从理论上讲,再次受孕的可能性最大。