An assessment of image quality from a direct radiological magnification method with a microfocus was carried out. It was found that direct magnification has advantages for the magnification of thin objects (5 cm. thickness). Because of the marked radiation scarrer in thick objects an improvement in picture quality is not possible. Scatter, despite the Groedel effect, is too large. Optimum results are obtained with a microfocus tube using universal screens. Comparable image quality is not possible with high intensification screens. High definition screens are not suitable for magnification. Dose measurements revealed unexpectedly low levels, particularly for thin objects. The reasons for this were examined and are described.
对采用微焦点的直接放射放大法的图像质量进行了评估。结果发现,直接放大对于薄物体(厚度5厘米)的放大具有优势。由于厚物体中存在明显的辐射散射,图像质量无法得到改善。尽管有格罗德尔效应,但散射仍然过大。使用通用增感屏的微焦点管可获得最佳结果。使用高增益增感屏无法获得可比的图像质量。高清晰度增感屏不适合用于放大。剂量测量显示出意外的低水平,尤其是对于薄物体。对此进行了原因检查并加以描述。