Nathan A W, Bexton R S, Levy A M, Parmar N, Camm A J
Pediatr Cardiol. 1984 Jan-Mar;5(1):7-12. doi: 10.1007/BF02306741.
Twenty-seven normal, nonsedated neonates had high-resolution electrocardiography performed during the first four days of life. Using high amplification, analogue and digital filters, and signal averaging, easily defined His bundle deflections of 0.75-7.75 (mean 2.5) microV were detected in 25 (92.6%) of the 27 babies. The PH interval was 60-105 (mean 83) ms and the HV interval 10-25 (mean 17) ms. Surface His bundle electrocardiography is easily performed in the neonate and, as might be predicted, conduction intervals are considerably shorter than those seen in older age groups.
27名正常、未使用镇静剂的新生儿在出生后的头四天内接受了高分辨率心电图检查。通过高放大倍数、模拟和数字滤波器以及信号平均技术,在27名婴儿中的25名(92.6%)检测到了易于定义的希氏束偏转,幅度为0.75 - 7.75(平均2.5)微伏。PH间期为60 - 105(平均83)毫秒,HV间期为10 - 25(平均17)毫秒。新生儿的体表希氏束心电图检查易于进行,正如预期的那样,传导间期明显短于年龄较大的人群。