Pantev C, Khvoles R
Scand Audiol. 1984;13(2):103-8. doi: 10.3109/01050398409043047.
Artifact rejection using various criteria has not yet been investigated comparatively in the determination of auditory brain-stem responses (ABR). The aim of this paper is to test the efficiency of three different criteria of artifact rejection: the 'level' criterion, the 'amplitude histogram' criterion, and the 'power' criterion, and to compare their practical applicability. With regard to the identification of the single waves of ABR (percentage frequency of their appearance) and their amplitudes without and with artifact rejection, it can be shown that the frequency of appearance increases severalfold when one of the artifact rejection criteria is used. The difference between amplitude means with artifact rejection (all three criteria) and those without artifact rejection is significant on the 5% level for waves I, II, and III and on the 1% level for wave V. When the three criteria are compared with regard to the amplitude means of the individual waves, it can be shown that the best results are obtained, when the 'level' criterion is used, then follows the 'power' criterion and third is the criterion of 'amplitude histogram'. The differences, however, are not significant. With reference to the 'level' criterion used, our investigation proved that the more complicated 'amplitude histogram' and 'power' criteria are not more efficient.
在听觉脑干反应(ABR)测定中,尚未对使用各种标准进行伪迹排除进行比较研究。本文的目的是测试三种不同伪迹排除标准的效率:“电平”标准、“幅度直方图”标准和“功率”标准,并比较它们的实际适用性。关于ABR单个波的识别(其出现的百分比频率)以及有无伪迹排除时它们的幅度,可以表明,当使用其中一种伪迹排除标准时,出现频率会增加几倍。对于I、II和III波,有伪迹排除(所有三种标准)时的幅度平均值与无伪迹排除时的幅度平均值之间的差异在5%水平上具有显著性,对于V波在1%水平上具有显著性。当比较这三种标准关于各个波的幅度平均值时,可以表明,使用“电平”标准时获得的结果最佳,其次是“功率”标准,第三是“幅度直方图”标准。然而,差异并不显著。关于所使用的“电平”标准,我们的研究证明,更复杂的“幅度直方图”和“功率”标准并不更有效。