Horstmann E
Z Kardiol. 1984 Jun;73(6):374-9.
The measurement of mean pulmonary artery pressure is an important parameter for the assessment of left ventricular function. Transthoracic impedance cardiography is a method which, by measurement of transthoracic impedance, gives information on hemodynamic events, parameters of contractility, and valvular heart disease. In 50 patients mean pulmonary artery pressure was measured at rest and during exercise and compared to the corresponding changes in the impedance cardiogram. It was examined whether by means of impedance cardiography an elevated pulmonary artery pressure could be predicted. Group I consisted of 25 patients with normal pulmonary artery pressure at rest and during exercise, group II of 25 patient with pathologic pressure elevation. While the behavior of stroke volume, cardiac output, left ventricular ejection time, and Heather Index as measured by impedance cardiography did not allow a prediction of elevated pulmonary artery pressure, the impedance ratio O/dz/dtmin (IQ) was significantly greater in group II than in group I. In the patients tested elevated and normal pulmonary artery pressure during exercise could be predicted with an accuracy of 84%. The mean value of dz/dtmin at a work load of 100 watt was slightly but significantly higher in group I than in group II. The results show that the impedance ratio (IQ) can be used to assess left ventricular function non-invasively.
平均肺动脉压的测量是评估左心室功能的一个重要参数。经胸阻抗心动图是一种通过测量经胸阻抗来获取血流动力学事件、收缩性参数和心脏瓣膜病相关信息的方法。对50例患者在静息和运动时测量平均肺动脉压,并与阻抗心动图的相应变化进行比较。研究是否可以通过阻抗心动图预测肺动脉压升高。第一组由25例静息和运动时肺动脉压正常的患者组成,第二组由25例肺动脉压病理性升高的患者组成。虽然通过阻抗心动图测量的每搏量、心输出量、左心室射血时间和希瑟指数的变化无法预测肺动脉压升高,但第二组的阻抗比O/dz/dtmin(IQ)显著高于第一组。在受试患者中,运动时肺动脉压升高和正常情况能够以84%的准确率被预测。在100瓦工作量时,第一组的dz/dtmin平均值略高于第二组,但差异具有统计学意义。结果表明,阻抗比(IQ)可用于无创评估左心室功能。