Reject analysis: its role in quality assurance.

作者信息

Watkinson S, Moores B M, Hill S J

出版信息

Radiography. 1984 Sep-Oct;50(593):189-94.

PMID:6484122
Abstract

A reject analysis has been undertaken for a 26 week period in the radiology department of an oncological centre. The overall reject and repeat rates are presented here, as well as those arising from individual examinations and X-ray rooms. The variations in reject rates for different examinations as a function of time are highlighted and the role of reject analysis in quality assurance is discussed.

摘要

相似文献

1
Reject analysis: its role in quality assurance.
Radiography. 1984 Sep-Oct;50(593):189-94.
2
[Analysis of reject x-ray films as a quality assurance element in diagnostic radiology].[将拒收的X光片作为诊断放射学质量保证要素的分析]
Rofo. 1997 May;166(5):376-81. doi: 10.1055/s-2007-1015445.
3
Films reject analysis for conventional radiography in Iranian main hospitals.在伊朗的主要医院中,X光片不适合用于传统X光摄影分析。
Radiat Prot Dosimetry. 2011 Sep;147(1-2):220-2. doi: 10.1093/rpd/ncr306. Epub 2011 Jul 14.
4
An audit of rejected repeated x-ray films as a quality assurance element in a radiology department.对放射科拒收的重复X光片进行审核,作为质量保证的一项内容。
Niger J Clin Pract. 2008 Dec;11(4):355-8.
5
Analysis of film reject rate in the diagnostic x-ray facility of a tertiary health institution in Benin, Nigeria.尼日利亚贝宁一家三级医疗机构诊断性X射线设备的胶片拒收率分析。
Nig Q J Hosp Med. 2013 Jan-Mar;23(1):54-7.
6
Analysis and Economic Implication of X-Ray Film Reject in Diagnostic Radiology Department of Jimma University Specialized Hospital, Southwest Ethiopia.埃塞俄比亚西南部吉马大学专科医院放射诊断科X线片拒收情况分析及其经济影响
Ethiop J Health Sci. 2017 Jul;27(4):421-426. doi: 10.4314/ejhs.v27i4.13.
7
Quality assurance--a study in radiography.质量保证——放射照相术研究
Radiogr Today. 1991 Jun;57(649):13-5.
8
Quality assurance in diagnostic radiography: are we using it correctly and what is its future?
Radiography. 1987 Jul-Aug;53(610):161-3.
9
Reject rate analysis in digital radiography: an Australian emergency imaging department case study.数字放射成像中的拒收率分析:澳大利亚一家急诊影像科的案例研究
J Med Radiat Sci. 2020 Mar;67(1):72-79. doi: 10.1002/jmrs.343. Epub 2019 Jul 18.
10
Routine quality assurance and results of a diagnostic radiology quality assurance programme.
Radiobiol Radiother (Berl). 1990;31(2):189-92.

引用本文的文献

1
Making the most of X-ray reject analysis in the digital age.充分利用数字时代的 X 射线 reject 分析。
J Med Radiat Sci. 2023 Jun;70(2):109-111. doi: 10.1002/jmrs.680. Epub 2023 Apr 16.
2
Digital radiography reject analysis of examinations with multiple rejects: an Australian emergency imaging department clinical audit.数字 X 射线摄影术多次废片的检查分析:澳大利亚急诊影像科临床审计。
J Med Radiat Sci. 2021 Sep;68(3):245-252. doi: 10.1002/jmrs.468. Epub 2021 Apr 7.
3
Determination and Analysis of Film Reject Rate at Eight Selected Governmental Diagnostic X-Ray Facilities in Tigray Region, Northern Ethiopian.
埃塞俄比亚北部提格雷地区八家选定的政府诊断性X射线设施的胶片拒收率测定与分析
J Med Phys. 2018 Oct-Dec;43(4):270-276. doi: 10.4103/jmp.JMP_40_18.
4
Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study.本科生使用互补金属氧化物半导体传感器进行口腔内数字成像的重复分析:一项机构案例研究。
Imaging Sci Dent. 2017 Dec;47(4):233-239. doi: 10.5624/isd.2017.47.4.233. Epub 2017 Dec 12.
5
Analysis and Economic Implication of X-Ray Film Reject in Diagnostic Radiology Department of Jimma University Specialized Hospital, Southwest Ethiopia.埃塞俄比亚西南部吉马大学专科医院放射诊断科X线片拒收情况分析及其经济影响
Ethiop J Health Sci. 2017 Jul;27(4):421-426. doi: 10.4314/ejhs.v27i4.13.
6
Repeat film analysis and its implications for quality assurance in dental radiology: An institutional case study.重复影像分析及其对口腔放射学质量保证的影响:一项机构案例研究。
Contemp Clin Dent. 2015 Jul-Sep;6(3):392-5. doi: 10.4103/0976-237X.161898.
7
Maintaining quality control using a radiological digital X-ray dashboard.使用放射数字X射线仪表盘维持质量控制。
J Digit Imaging. 2009 Mar;22(1):84-8. doi: 10.1007/s10278-007-9098-4. Epub 2008 Feb 13.
8
Overexposure to radiology.过度暴露于放射学检查。
Br Med J (Clin Res Ed). 1987 Nov 7;295(6607):1162-3. doi: 10.1136/bmj.295.6607.1162.