Jones W, Gamble J
Environ Res. 1984 Oct;35(1):1-10. doi: 10.1016/0013-9351(84)90110-5.
Industrial hygiene measurements were taken at five lead acid battery plants. The average of all personal samples for H2SO4 was 0.18 mg/m3 with a range of "nondetectable" to 1.7 mg/m3. Highest levels of acid were found in the charging and forming areas of the plants. Stibine and arsine were also detected in the charging and forming areas (means = 0.44 and 0.042 mg/m3, respectively). Arsenic in particulate form was also detected, but levels were low (means = 0.00083 mg/m3). The average mass median aerodynamic diameter of the acid mist as measured by cascade impactors was approximately 5 micron. Air lead results were variable with an overall average of 0.072 mg/m3 and a standard deviation of 0.11 mg/m3.
在五家铅酸电池厂进行了工业卫生测量。所有硫酸个人样本的平均值为0.18毫克/立方米,范围为“未检出”至1.7毫克/立方米。在工厂的充电和成型区域发现了最高水平的酸。在充电和成型区域也检测到了锑化氢和砷化氢(平均值分别为0.44和0.042毫克/立方米)。还检测到了颗粒形式的砷,但含量很低(平均值为0.00083毫克/立方米)。用多级冲击器测量的酸雾平均质量中值空气动力学直径约为5微米。空气中铅的结果各不相同,总体平均值为0.072毫克/立方米,标准偏差为0.11毫克/立方米。