Wilke T J, Hirning D A
Clin Biochem. 1984 Oct;17(5):311-6. doi: 10.1016/s0009-9120(84)90625-8.
We evaluated Amerlex (Amersham International), Corti-Shure (Nuclear Medical Laboratories), Gammacoat (Clinical Assays), Coat-A-Count and DPC-direct (Diagnostic Products Corporation) radioimmunoassay kits for determination of cortisol in sera. The between- and within-batch precision (coefficient of variation) ranged between 4.4-12.5% and 3.0-10.9% respectively. No one kit exhibited a clearly better precision throughout the assay range. All kits displayed good sensitivity and parallelism. Cortisol concentrations determined by kit methods, in two assayed control sera, were 3-14% higher than by gas chromatography/mass spectrometry. Coat-A-Count and Gammacoat were technically the simplest assays while Corti-Shure and DPC-direct kits had the best designed standard curves over the diagnostic range. The Amerlex kit had the greatest sensitivity, showed least shift in the dose-response curve between assay and was the only assay that came to equilibrium within the specified incubation time.
我们评估了用于测定血清中皮质醇的Amerlex(阿美仙国际公司)、Corti-Shure(核医学实验室)、Gammacoat(临床检测公司)、Coat-A-Count和DPC-direct(诊断产品公司)放射免疫分析试剂盒。批间和批内精密度(变异系数)分别在4.4%至12.5%和3.0%至10.9%之间。在整个测定范围内,没有一种试剂盒表现出明显更好的精密度。所有试剂盒均显示出良好的灵敏度和平行性。通过试剂盒方法测定的两种检测对照血清中的皮质醇浓度比气相色谱/质谱法高3%至14%。Coat-A-Count和Gammacoat在技术上是最简单的检测方法,而Corti-Shure和DPC-direct试剂盒在诊断范围内具有设计最佳的标准曲线。Amerlex试剂盒具有最高的灵敏度,在测定之间剂量反应曲线的偏移最小,并且是唯一在规定孵育时间内达到平衡的检测方法。