反相离子对高效液相色谱法分离血红素化合物及其在铁螯合酶活性测定中的应用。

Separation of haem compounds by reversed-phase ion-pair high-performance liquid chromatography and its application in the assay of ferrochelatase activity.

作者信息

Tangerås A

出版信息

J Chromatogr. 1984 Sep 14;310(1):31-9. doi: 10.1016/0378-4347(84)80065-1.

Abstract

The separation of haems and porphyrins was achieved in a reversed-phase ion-pair high-performance liquid chromatography system using tetrabutylammonium hydrogen sulphate as the pairing ion. The concentration of methanol and pH in the mobile phase were determinative parameters for the elution pattern of the compounds. Two isocratic systems--one for the assay of protohaem IX and one for deuterohaem IX--were developed. The chromatographic systems were applied to the assay of ferrochelatase activity in mitochondria using either protoporphyrin or deuteroporphyrin as the substrate. The ferrochelatase activity was also measured in reticulocytes, which contain high levels of endogenous haem.

摘要

使用硫酸氢四丁铵作为配对离子,在反相离子对高效液相色谱系统中实现了血红素和卟啉的分离。流动相中甲醇的浓度和pH值是这些化合物洗脱模式的决定性参数。开发了两种等度洗脱系统——一种用于原血红素IX的测定,另一种用于氘代血红素IX的测定。这些色谱系统用于以原卟啉或氘代卟啉为底物测定线粒体中的亚铁螯合酶活性。还在含有高水平内源性血红素的网织红细胞中测量了亚铁螯合酶活性。