Cummings J, Stuart J F, Calman K C
J Chromatogr. 1984 Nov 9;311(1):125-33. doi: 10.1016/s0378-4347(00)84698-8.
A reversed-phase isocratic high-performance liquid chromatographic assay is described for the measurement of adriamycin, adriamycinol and their 7-deoxyaglycones in human serum. The lower limit of detection in serum is 3 ng/ml for adriamycin and 1 ng/ml for adriamycinol and the 7-deoxyaglycones with coefficients of variation for k' of less than 5% throughout the day. An extraction technique for serum is described which is capable of an almost equal recovery (greater than 77%) of adriamycin, metabolites and daunorubicin (the internal standard) without interference from endogenous components of serum. Serum concentrations of metabolites 15 min after intravenous bolus administration of 40 mg/m2 adriamycin in two different patients were 26.5 and 16.6 ng/ml for adriamycinol; 109.8 and 5.8 ng/ml for the adriamycinol 7-deoxyaglycone and 21.4 and 17.1 ng/ml for the adriamycin 7-deoxyaglycone. A total of six metabolites of adriamycin were detected in the two patients using this methodology.
本文描述了一种反相等度高效液相色谱法,用于测定人血清中的阿霉素、阿霉素醇及其7-脱氧糖苷配基。血清中阿霉素的检测下限为3 ng/ml,阿霉素醇及其7-脱氧糖苷配基的检测下限为1 ng/ml,全天k'的变异系数小于5%。本文还描述了一种血清提取技术,该技术能够使阿霉素、代谢物和柔红霉素(内标)的回收率几乎相等(大于77%),且不受血清内源性成分的干扰。在两名不同患者中静脉推注40 mg/m²阿霉素15分钟后,血清中阿霉素醇的浓度分别为26.5和16.6 ng/ml;阿霉素醇7-脱氧糖苷配基的浓度分别为109.8和5.8 ng/ml;阿霉素7-脱氧糖苷配基的浓度分别为21.4和17.1 ng/ml。使用该方法在两名患者中共检测到六种阿霉素代谢物。