Suppr超能文献

采用蒸气压渗透法和平衡透析法研究药物-辅料相互作用的对比研究

[Comparative studies on the study of drug-excipient interactions with vapor pressure osmometry and equilibrium dialysis].

作者信息

Voigt R, Pergande G, Keipert S

出版信息

Pharmazie. 1984 Nov;39(11):760-3.

PMID:6531380
Abstract

The authors discuss how far the vapour osmometry enables to make statements on the interaction between drugs and macromolecular agents as well as on their dependence upon various test parameters. The results are compared to those of the equilibrium dialysis. Sulfathiazole sodium and the polyvinylpyrrolidones PVP K 25 and PVP K 90 are used the sample substances. Concerning the interaction dependence upon the concentrations of drugs or agents, resp., both the methods revealed findings of comparable trends. An increased agent concentration or a reduced drug concentration results in an increased sulfathiazole-PVP interaction. An exothermic binding process can be derived from tonometric and dialysis results. Vapour osmometric measurements not only restricting to the interactions drugs-agents, but also recording all the interactions caused by variations of the particle number, the findings obtained by means of buffered solution do not permit a comparability of both the methods. Although the equilibrium dialysis takes precedence in the exact registration of drug-agent interactions, the vapour osmometry has an advantage in the registration of drug interactions with membrane-permeating agents.

摘要

作者们讨论了蒸汽渗透压法在阐述药物与大分子试剂之间的相互作用以及它们对各种测试参数的依赖性方面的能力。将结果与平衡透析的结果进行了比较。使用磺胺噻唑钠以及聚乙烯吡咯烷酮PVP K 25和PVP K 90作为样品物质。关于相互作用对药物或试剂浓度的依赖性,两种方法都揭示了具有可比趋势的结果。试剂浓度增加或药物浓度降低会导致磺胺噻唑 - PVP相互作用增加。可以从张力测定和透析结果推导出放热结合过程。蒸汽渗透压测量不仅限于药物 - 试剂相互作用,还记录了由粒子数变化引起的所有相互作用,通过缓冲溶液获得的结果不允许两种方法具有可比性。尽管平衡透析在药物 - 试剂相互作用的精确记录方面占优势,但蒸汽渗透压法在记录药物与膜渗透剂的相互作用方面具有优势。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验