Yu Y L, du Boulay G H
Neuroradiology. 1984;26(5):399-403. doi: 10.1007/BF00327494.
The safety of post-myelogram computed tomography (PMCT) as an additional diagnostic procedure to metrizamide myelography was evaluated. One hundred and four consecutive patients with suspected cervical cord lesions were studied prospectively; 50 had both myelography and PMCT, and the 54 acting as controls had only myelography. PMCT did not increase the incidence, severity or duration of common side effects and the majority of patients accepted this additional procedure. It is concluded that as long as care is taken to avoid the occurrence of excessive contrast in the intracranial subarachnoid space, PMCT is a safe procedure.
对作为甲泛葡胺脊髓造影附加诊断程序的脊髓造影后计算机断层扫描(PMCT)的安全性进行了评估。对104例连续的疑似颈髓病变患者进行了前瞻性研究;50例患者同时接受了脊髓造影和PMCT,另外54例作为对照仅接受了脊髓造影。PMCT并未增加常见副作用的发生率、严重程度或持续时间,并且大多数患者接受了这一附加程序。结论是,只要注意避免颅内蛛网膜下腔出现过量造影剂,PMCT就是一种安全的程序。