Fonseca-Costa A, Magrassi P, Zin W A, Romêo L J
Am J Physiol. 1984 Oct;247(4 Pt 2):H517-22. doi: 10.1152/ajpheart.1984.247.4.H517.
In six anesthetized dogs 70 indicator-dilution curves and phase-plane plots were recorded. Indocyanine green was injected into the superior vena cava and sampled through a dichromatic cuvette densitometer from the femoral artery. Dye-dilution curves were recorded from dogs with normal cardiovascular systems and repeated after right-to-left shunts of different magnitude were surgically produced. The percent of blood shunting was calculated according to standard indicator-dilution equations and also by means of oximetric determination of blood samples. They were compared with shunt estimates based on phase-plane loop measurements. Good correlation was found with standard indicator-dilution procedures (r = 0.890) but not with oximetry (r = 0.466). The phase plane shows its utility in the detection and evaluation of small right-to-left shunts. These shunts affect the initial portion of the phase plane and the alterations appear to be more evident than in the corresponding concentration-vs.-time curves.
在6只麻醉犬身上记录了70条指示剂稀释曲线和相平面图。将吲哚菁绿注入上腔静脉,并通过双色比色皿密度计从股动脉采样。记录了具有正常心血管系统的犬的染料稀释曲线,并在通过手术制造不同程度的右向左分流后重复进行记录。根据标准指示剂稀释方程以及通过对血样进行血氧测定来计算分流的血液百分比。将它们与基于相平面环测量的分流估计值进行比较。发现与标准指示剂稀释程序具有良好的相关性(r = 0.890),但与血氧测定法没有相关性(r = 0.466)。相平面显示出其在检测和评估小的右向左分流中的效用。这些分流影响相平面的初始部分,并且这些改变似乎比相应的浓度-时间曲线中更明显。