Dunlop C I, Hodgson D S, Chapman P L, Grandy J L, Waldron R D
Department of Clinical Sciences, Colorado State University, Fort Collins 80523.
Am J Vet Res. 1991 Nov;52(11):1893-7.
The purpose of this study was to compare the thermodilution technique for estimation of cardiac output with the indocyanine green dye dilution technique at flows between 10 and 39 L/min in halothane-anesthetized horses. The estimation of area of dye dilution cardiac output curves was made by using the fore-'n-aft (FA) triangle method. This shorthand technique was compared with logarithmic exponential extrapolation and summation (extrapolated area), using 64 cardiac output curves. Then, 256 simultaneous thermodilution measurements were compared with dye dilution measurements calculated by use of the FA technique. Forty milliliters of iced 0.9% NaCl solution containing 15 mg of indocyanine green dye was used as the indicator. This was delivered in less than 1 second to the right atrium, using a power injector. A thermistor positioned in the pulmonary artery detected the thermal indicator. Blood was withdrawn from the carotid artery through a densitometer cuvette to measure the dye concentration. The FA estimations of area were higher than those determined by use of extrapolated area. A multiplicative adjustment of 0.837 was estimated. On average, thermodilution estimates of cardiac output exceeded the adjusted FA determinations. Using a weighted linear regression, we determined the following calibration adjustment: thermal dilution cardiac output/1.048 = indocyanine green dye dilution cardiac output.
本研究的目的是在氟烷麻醉的马匹中,比较热稀释技术与吲哚菁绿染料稀释技术在10至39升/分钟流量下对心输出量的估计。染料稀释心输出量曲线面积的估计采用前后(FA)三角形法。使用64条心输出量曲线,将这种简捷技术与对数指数外推法和求和法(外推面积)进行比较。然后,将256次同步热稀释测量结果与使用FA技术计算的染料稀释测量结果进行比较。使用含15毫克吲哚菁绿染料的40毫升冰0.9%氯化钠溶液作为指示剂。使用动力注射器在不到1秒的时间内将其注入右心房。置于肺动脉的热敏电阻检测热指示剂。通过密度计比色皿从颈动脉取血以测量染料浓度。FA法对面积的估计高于外推面积法确定的值。估计乘法调整系数为0.837。平均而言,热稀释法对心输出量的估计超过了调整后的FA法测定值。使用加权线性回归,我们确定了以下校准调整:热稀释心输出量/1.048 = 吲哚菁绿染料稀释心输出量。