Suppr超能文献

血浆中胰高血糖素样肽I(PHI)特异性放射免疫分析方法的建立与验证

Development and validation of a specific radioimmunoassay for PHI in plasma.

作者信息

Fahrenkrug J, Pedersen J H

出版信息

Clin Chim Acta. 1984 Nov 30;143(3):183-92. doi: 10.1016/0009-8981(84)90068-8.

Abstract

A sensitive and specific radioimmunoassay for the recently isolated neuropeptide with N-terminal histidine and C-terminal isoleucine amide (PHI) has been developed which can detect 3.0 pmol/l of the peptide in plasma. The routine antiserum produced in rabbit had a titre of 1:800 000 and recognized the sequence 3-8 of the 27 amino acid peptide. Labelling of PHI with 125I was performed by the chloramine T method, and labelled PHI was separated from unlabelled on an octadecylsilyl (ODC)-silica column. Non-specific interference in the assay was excluded by extraction of plasma with ethanol to a mean recovery of 82.4%. Plasma samples diluted parallel to the standard curve and behaved as PHI on ODC-silica column. The intra-assay and inter-assay coefficient of variation (CV) values at a level of 24.0 pmol/l were 6.3% and 13.1%, respectively. In 75 normal adults, the fasting PHI concentration ranged from 3.5-30.0 pmol/l with a mean of 14.2 pmol/l. In 235 children, the PHI concentration varied with age. Ingestion of a meal caused a rapid and short-lived increase in the PHI concentration.

摘要

已开发出一种灵敏且特异的放射免疫分析法,用于检测最近分离出的一种神经肽,该神经肽的N端为组氨酸,C端为异亮氨酸酰胺(PHI),它能够检测出血浆中3.0皮摩尔/升的该肽。在兔体内产生的常规抗血清效价为1:800 000,可识别27个氨基酸肽的3 - 8序列。用氯胺T法对PHI进行125I标记,并在十八烷基硅烷(ODC)硅胶柱上分离标记的PHI与未标记的。通过用乙醇提取血浆来排除测定中的非特异性干扰,平均回收率为82.4%。血浆样本与标准曲线平行稀释,在ODC硅胶柱上的行为与PHI一致。在24.0皮摩尔/升水平时,批内和批间变异系数(CV)值分别为6.3%和13.1%。在75名正常成年人中,空腹时PHI浓度范围为3.5 - 30.0皮摩尔/升,平均为14.2皮摩尔/升。在235名儿童中,PHI浓度随年龄变化。进食一顿饭后,PHI浓度会迅速且短暂升高。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验