Jensen J S
Acta Orthop Scand. 1978 Feb;49(1):54-9. doi: 10.3109/17453677809005724.
In attempt to standardize an experimental model for biomechanical studies of unstable trochanteric fractures, acrylic models of the proximal femur were investigated by the photoelastic technique. By matching the stress distribution in the acrylic models to those calculated by Pauwels, it was found that the optimal femoral shaft and resultant hip joint force angles were 5 degrees and 6 degrees to the vertical, respectively. The abductor muscle pull was determined to be 55 per cent of the resultant hip joint force at 15 degrees medial inclination to the vertical.
为了使不稳定型股骨转子间骨折生物力学研究的实验模型标准化,采用光弹性技术对股骨近端的丙烯酸模型进行了研究。通过将丙烯酸模型中的应力分布与 Pauwels 计算的应力分布相匹配,发现最佳股骨干与合成髋关节力角度分别与垂线呈 5 度和 6 度。确定外展肌拉力为合成髋关节力的 55%,垂直方向内侧倾斜 15 度。