Pereira W, Kovnat D M, Snider G L
Chest. 1978 Jun;73(6):813-6. doi: 10.1378/chest.73.6.813.
The frequency of complications following flexible fiber-optic bronchoscopic procedures was studied prospectively in 908 patients from 13 cooperating hospitals. Major complications (respiratory arrest, pneumonia, pneumothorax, and obstruction of airways) occurred in 1.7 per cent (15) of the procedures. There was one death, yielding a mortality of 0.1%. Minor complications, including vasovagal reactions, fever, cardiac arrhythmias, bleeding, obstruction of airways, nausea and vomiting, pneumothorax, psychotic reaction, and aphonia, occurred in 6.5% of the procedures. Pneumothorax occurred after 5% (four) of 85 transbronchial biopsies. Although serious complications occur more frequently than previously reported from retrospective studies, complications after fiberoptic bronchoscopic procedures are still quite infrequent. The relative risks and benefits must always be carefully weighed in patients being considered for a fiberoptic bronchoscopic procedure.
对来自13家合作医院的908例患者进行了前瞻性研究,以探讨柔性纤维支气管镜检查术后并发症的发生率。主要并发症(呼吸骤停、肺炎、气胸和气道梗阻)在1.7%(15例)的检查中出现。有1例死亡,死亡率为0.1%。轻微并发症,包括血管迷走神经反应、发热、心律失常、出血、气道梗阻、恶心和呕吐、气胸、精神反应和失音,在6.5%的检查中出现。85例经支气管活检中有5%(4例)发生气胸。尽管严重并发症的发生率比以往回顾性研究报告的要高,但纤维支气管镜检查术后的并发症仍然相当少见。对于考虑进行纤维支气管镜检查的患者,必须始终仔细权衡相对风险和益处。