放射造影剂对血清补体系统的影响。

Effects of radiographic contrast media on the serum complement system.

作者信息

Tirone P, Boldrini E

出版信息

Arch Toxicol Suppl. 1983;6:37-41. doi: 10.1007/978-3-642-69083-9_5.

Abstract

The authors explored the activation of the complement system produced by a nonionic organic iodine compound, namely iopamidol, which is proposed as a contrast medium for radiographic examination by intravenous and intra-arterial injection. The study was conducted in vitro versus established ionic contrasts (diatrizoate, iothalamate, acetrizoate) and a nonionic compound (metrizamide). The adopted experimental model was the immunohemolytic detector system, in which the immune complex consisted of goat erythrocytes sensitized with the corresponding antibody (hemolysin), and complement (C') was supplied by guinea pig serum. All the products caused complement activation. The results show that nonionic contrast media produce less activation of the complement system than the traditional ionic contrast. Thus the use of nonionic contrast for radiological procedures necessitating the introduction of contrast material into the blood compartment would imply a reduced risk of anaphylactoid reactions.

摘要

作者探讨了一种非离子型有机碘化合物(即碘帕醇)所产生的补体系统激活情况。碘帕醇被提议作为通过静脉内和动脉内注射用于放射检查的造影剂。该研究是在体外针对已有的离子型造影剂(泛影葡胺、异泛影葡胺、醋碘苯酸)和一种非离子型化合物(甲泛葡胺)进行的。所采用的实验模型是免疫溶血检测系统,其中免疫复合物由用相应抗体(溶血素)致敏的山羊红细胞组成,补体(C')由豚鼠血清提供。所有产品均引起补体激活。结果表明,与传统离子型造影剂相比,非离子型造影剂产生的补体系统激活较少。因此,在需要将造影剂引入血液腔室的放射学检查中使用非离子型造影剂意味着类过敏反应风险降低。