Thiamine whole blood pharmackinetics in rats using both a specific S-thiamine liquid scintillation assay and the thiochrome fluorescence assay.

作者信息

Pipkin J D, Stella V J

出版信息

J Pharm Sci. 1978 Jun;67(6):818-21. doi: 10.1002/jps.2600670624.

DOI:10.1002/jps.2600670624
PMID:660465
Abstract

The study of factors altering the CNS and GI absorption of thiamine in rats required the development of a specific assay for thiamine from 100-microliter samples of blood and plasma and small quantities of tissue. The specific thiochrome fluorescence assay for thiamine was modified to handle microsamples and to use S-thiamine. This sensitive and specific radioassay using S-thiamine gave pharmacokinetic parameters for 4-mg/kg iv doses of thiamine in rats equivalent to those using the less sensitive thiochrome fluorescence assay. The new assay, because of its lower limit of detection, allowed the study of the time profile of thiamine after a 1-mg/kg iv dose in rats. Such a time profile could not have been followed using the standard thiochrome fluorescence assay.

摘要

相似文献

1
Thiamine whole blood pharmackinetics in rats using both a specific S-thiamine liquid scintillation assay and the thiochrome fluorescence assay.
J Pharm Sci. 1978 Jun;67(6):818-21. doi: 10.1002/jps.2600670624.
2
A reliable semiautomated method for the determination of total thiamine in whole blood by the thiochrome method with high-performance liquid chromatography.一种采用硫色素法结合高效液相色谱法测定全血中总硫胺素的可靠半自动方法。
Ann Clin Biochem. 1982 Jan;19(Pt 1):52-6. doi: 10.1177/000456328201900111.
3
Determination of urinary thiamine by high-pressure liquid chromatography utilizing the thiochrome fluorscent method.
J Chromatogr. 1978 Jul 1;146(1):43-53. doi: 10.1016/s0378-4347(00)81288-8.
4
[Observations on the determination of thiamine in serum by the thiochrome method (author's transl)].
Z Klin Chem Klin Biochem. 1974 Oct;12(10):437-9.
5
Comparison of manual and benzenesulfonyl chloride-semiautomated thiochrome methods for determination of thiamine in foods.
J Assoc Off Anal Chem. 1981 May;64(3):616-22.
6
Determination of thiamine in human plasma and its pharmacokinetics.
Eur J Clin Pharmacol. 1985;28(2):213-9. doi: 10.1007/BF00609694.
7
[Aspects of the biological activity of thiochrome].
Vopr Pitan. 1979 Jan-Feb(1):22-6.
8
Detection of minute thiamine concentrations via thiochrome assay.
J Assoc Off Anal Chem. 1971 Jan;54(1):211-2.
9
Determination of thiamine in pharmaceutical preparations by sequential injection renewable surface solid-phase spectrofluorometry.采用顺序注射可再生表面固相荧光光谱法测定药物制剂中的硫胺素。
Anal Sci. 2003 Feb;19(2):289-94. doi: 10.2116/analsci.19.289.
10
Modified thiochrome procedure for the determination of urinary thiamin.
Am J Clin Nutr. 1972 Mar;25(3):273-4. doi: 10.1093/ajcn/25.3.273.