Performance of collimators used for tomographic imaging of I-123 contaminated with I-124.

作者信息

Polak J F, English R J, Holman B L

出版信息

J Nucl Med. 1983 Nov;24(11):1065-9.

PMID:6605417
Abstract

Iodine-123 prepared from the 124Te(p,2n)123I reaction is contaminated with between 3% to 5% I-124 when imaging is performed. The effects of such a mixture were evaluated for medium-energy and low energy general-purpose collimators on a commercially available rotating gamma camera equipped to perform tomography. The planar sensitivity for I-123 was less for the general-purpose collimator, varying between 0.84 and 0.85 in water relative to that measured for the medium energy-collimator. Counts due to scattering or septal penetration of I-124 photons were greater for the general-purpose collimator (36%) than for the medium-energy collimator (15%). Evaluation of the higher-frequency components of the modulation transfer functions confirmed that the low-energy general-purpose collimator is expected to offer significantly more contrast information at frequencies above 0.21 cycles/cm. This is expected to contribute to image quality when studies are performed with collimators of similar design.

摘要

相似文献

1
Performance of collimators used for tomographic imaging of I-123 contaminated with I-124.
J Nucl Med. 1983 Nov;24(11):1065-9.
2
Comparison of low- and medium-energy collimators for SPECT imaging with iodine-123-labeled antibodies.
J Nucl Med. 1986 Sep;27(9):1467-74.
3
[Performance of gamma camera collimators used for single photon emission computed tomography imaging with 123I-isopropyl iodoamphetamine].
Radioisotopes. 1986 May;35(5):256-62. doi: 10.3769/radioisotopes.35.5_256.
4
Slit slat collimator optimization with respect to MTF.狭缝平板准直器关于调制传递函数的优化。
Appl Radiat Isot. 2005 Mar;62(3):461-8. doi: 10.1016/j.apradiso.2004.07.009.
5
Collimation for imaging the myocardium. II.用于心肌成像的准直。二。
J Nucl Med. 1976 Aug;17(8):719-23.
6
Nonistropic point spread function as a result of collimator design and manufacturing defects.
J Nucl Med. 1988 Jun;29(6):1096-100.
7
Significance of radiocontaminants in 123I for dosimetry and scintillation camera imaging.
J Nucl Med. 1976 Aug;17(8):740-3.
8
I-123 HIPDM brain imaging with a rotating gamma camera and slant-hole collimator.使用旋转伽马相机和斜孔准直器进行I-123 HIPDM脑成像。
J Nucl Med. 1984 Apr;25(4):495-8.
9
SPECT imaging of high energy isotopes and isotopes with high energy contaminants with rotating slat collimators.使用旋转板准直器对高能同位素和带有高能污染物的同位素进行单光子发射计算机断层扫描(SPECT)成像。
Med Phys. 2009 Sep;36(9):4257-67. doi: 10.1118/1.3177312.
10
Monte Carlo simulation of energy spectra for (123)I imaging.用于(123)I成像的能谱蒙特卡罗模拟。
Phys Med Biol. 2007 Aug 7;52(15):4409-25. doi: 10.1088/0031-9155/52/15/004. Epub 2007 Jun 26.

引用本文的文献

1
Optimal collimator choice for sequential iodine-123 and technetium-99m imaging.
Eur J Nucl Med. 1996 Jul;23(7):768-74. doi: 10.1007/BF00843705.