Rumancik W M, Denlinger J K, Nahrwold M L, Falk R B
JAMA. 1978 Jul 28;240(4):366-8.
The correlation between serum ionized calcium (Ca++) levels and three ECG QT intervals (Q-OTC, Q-ATC, and Q-ETC) was assessed in 20 adult patients. The relationship between each QT interval and Ca++ level, based on 209 Ca++ determinations through a range of 1.0 to 4.0 mEq/liter, is best described by a hyperbolic function. Although Q-OTC and Q-ATC predict Ca++ levels more accurately than Q-ETC, all QT intervals are clinically unreliable as guides to the presence of hypercalcemia. Similarly, the usefulness of the QT intervals in the diagnosis of hypocalcemia is limited by the wide distribution of normal values.
对20名成年患者的血清离子钙(Ca++)水平与三个心电图QT间期(Q-OTC、Q-ATC和Q-ETC)之间的相关性进行了评估。基于在1.0至4.0毫当量/升范围内进行的209次Ca++测定,每个QT间期与Ca++水平之间的关系最好用双曲线函数来描述。尽管Q-OTC和Q-ATC比Q-ETC更准确地预测Ca++水平,但作为高钙血症存在的指标,所有QT间期在临床上都不可靠。同样,QT间期在低钙血症诊断中的实用性也受到正常值广泛分布的限制。