Suppr超能文献

使用扫频调频掩蔽器对听力正常的受试者进行频率选择性测试:初步报告。

Frequency selectivity in normal-hearing listeners using a sweep, frequency-modulated masker: a preliminary report.

作者信息

McDonald J M

出版信息

Ear Hear. 1983 Jul-Aug;4(4):209-11. doi: 10.1097/00003446-198307000-00007.

Abstract

It was the objective of this preliminary investigation to determine whether psychoacoustic tuning curves could be obtained on naive listeners utilizing a sweep, frequency-modulated masker. Psychoacoustic tuning curves were obtained on 10 normal-hearing young adult listeners. A simultaneous masking paradigm was utilized. The probe tone was a 2 kHz signal and the masker was a sweep, frequency-modulated tone between and including 750 Hz and 4 kHz. A mean Q value of 4.93 with a standard deviation of 0.85 was obtained from the subjects. Clinical implications and needs for further research are discussed.

摘要

本次初步调查的目的是确定能否利用扫频调频掩蔽器在未经训练的听众身上获得心理声学调谐曲线。在10名听力正常的年轻成年听众身上获得了心理声学调谐曲线。采用了同时掩蔽范式。探测音是一个2kHz的信号,掩蔽器是一个在750Hz至4kHz之间(包括750Hz和4kHz)扫频的调频音。受试者的平均Q值为4.93,标准差为0.85。讨论了临床意义和进一步研究的需求。