Johnson G L, Breart G L, Gewitz M H, Brenner J I, Lang P, Dooley K J, Ellison R C
Pediatrics. 1983 Dec;72(6):864-71.
As part of a multicenter collaborative study, M-mode echocardiograms were obtained shortly after birth on 3,559 premature infants with birth weight less than or equal to 1,750 g. Of these infants, 1,496 did not develop a cardiac murmur or other signs of a "hemodynamically significant" patent ductus arteriosus (PDA). Echocardiographic parameters from this "normal" group were compared with results obtained from 415 infants in whom PDA was diagnosed on the basis of clinical findings alone, irrespective of the echocardiogram (PDA group). The best discrimination between the two groups, when considering a single parameter, was provided by a left atrial to aortic root ratio (LA/AO) of 1.40, a left ventricular to aortic root ratio (LV/AO) of 2.10, or a left ventricular systolic time interval ratio (LPEP/LVET) of 0.27. Multivariate analysis demonstrated that better separation between the two groups occurred when the left atrial to aortic root ratio and the left ventricular systolic time interval ratio were considered jointly. Because of a large degree of overlap of all echocardiographic variables between the normal group and the group with PDA, the echocardiogram alone was not a good indicator of PDA. However, when used in conjunction with a priori estimates of the probability of PDA (based, for example, on birth weight and degree of respiratory disease), use of echocardiographic data was found to improve the detection of hemodynamically significant patent ductus arteriosus in premature infants.
作为一项多中心合作研究的一部分,对出生体重小于或等于1750克的3559名早产儿在出生后不久进行了M型超声心动图检查。在这些婴儿中,1496名未出现心脏杂音或其他“血流动力学显著”动脉导管未闭(PDA)的体征。将这个“正常”组的超声心动图参数与仅根据临床发现(无论超声心动图结果如何)诊断为PDA的415名婴儿的结果进行了比较(PDA组)。在考虑单个参数时,两组之间的最佳区分是由左心房与主动脉根部比值(LA/AO)为1.40、左心室与主动脉根部比值(LV/AO)为2.10或左心室收缩时间间期比值(LPEP/LVET)为0.27提供的。多变量分析表明,当联合考虑左心房与主动脉根部比值和左心室收缩时间间期比值时,两组之间能更好地分离。由于正常组和PDA组之间所有超声心动图变量存在很大程度的重叠,仅靠超声心动图并不是PDA的良好指标。然而,当与PDA发生概率的先验估计(例如基于出生体重和呼吸系统疾病程度)结合使用时,发现超声心动图数据的使用可改善对早产儿血流动力学显著动脉导管未闭的检测。