A new technique to measure the performance of local exhaust ventilation systems has been developed and tested in both the laboratory and the field. The technique involves the measurement of the capture efficiency of exterior hoods, defined to be the fraction of contaminants given off by a process captured by the exhaust system serving that process. Capture efficiency measurement can be a powerful tool in the evaluation of local exhaust systems, since it is a direct, quantitative measure of system performance; in contrast, indices of performance now in use are either qualitative or measure quantities which may not be related directly to system performance. A basic theory for capture efficiency has been developed, and a prototype system for measuring capture efficiency has been constructed and tested. Preliminary laboratory and field measurements using the system have demonstrated the power of the method, which should find widespread use in the design of new ventilation systems and the evaluation of existing ones.

摘要

一种用于测量局部排风通风系统性能的新技术已被开发出来,并在实验室和现场进行了测试。该技术涉及对外部通风罩捕集效率的测量,捕集效率定义为某一工艺产生的污染物被为该工艺服务的排风系统捕集的比例。捕集效率测量在局部排风系统评估中可能是一个有力工具,因为它是系统性能的直接定量测量;相比之下,目前使用的性能指标要么是定性的,要么测量的量可能与系统性能没有直接关系。已开发出捕集效率的基本理论,并构建和测试了一个用于测量捕集效率的原型系统。使用该系统进行的初步实验室和现场测量证明了该方法的有效性,该方法应会在新通风系统设计和现有通风系统评估中得到广泛应用。