Ann Thorac Surg. 1983 Dec;36(6):718-9. doi: 10.1016/s0003-4975(10)60285-8.
Clamping an atherosclerotic aorta during a cardiac operation exposes the patient to the risk of embolization of atherosclerotic debris. A method of internal occlusion using a Foley catheter is described that minimizes both trauma to the aorta and the associated risks of embolization.
心脏手术期间钳夹动脉粥样硬化的主动脉会使患者面临动脉粥样硬化碎片栓塞的风险。本文描述了一种使用Foley导管进行内部闭塞的方法,该方法可将对主动脉的创伤以及相关的栓塞风险降至最低。