Merrett J, Merrett T G
Clin Allergy. 1978 May;8(3):235-40. doi: 10.1111/j.1365-2222.1978.tb03219.x.
A single in vitro screening test for atopic allergy is described. It uses the radioallergosorbent test (RAST) principle, and has been applied to screening sera from U.K. patients with possible atopic symptoms. When compared with the Phadebas RAST, the test sensitivity was 97% and the specificity 100%, and these results suggest that it is useful in any preliminary allergy investigation.
本文描述了一种用于特应性过敏的体外筛选试验。该试验采用放射变应原吸附试验(RAST)原理,并已应用于筛选英国有特应性症状患者的血清。与Phadebas RAST相比,该试验的敏感性为97%,特异性为100%,这些结果表明它在任何初步过敏调查中都很有用。